Product Name |
Smoke Alarm |
Type |
Photoelectric |
Intent Use |
Residential Fire Safety |
Complied Standard |
EN14604:2005/AC:2008, NTN 167-L 2017 Rev 2nd |
Certificates |
CPR Certificate, Bosec Mark Cert |
Wireless Frequency Band |
RF 868 MHz |
Wireless Distance |
>100m in open area |
Suggested Interconnected Units |
<48 pcs |
Size |
φ120*35mm |
Color |
White RAL9010 |
Net weight |
107g (without battery) |
Power Supply |
2 pcs 1.5V replaceable battery with 5/10-year lifetime |
Hush Mode |
10-min silence for false alarm cause by other smoke |
Non-disturb Mode | 10-hour silence for fault or low battery voltage alarm to ensure good night |
Anti-tamper Function | yes |
Low Battery Voltage & fault indicator |
yes |
Alarm sensitivity |
0.100-0.160dB/m |
Alarm Volume |
>85dB(A) at 3 meters. |
Operation current |
<15uA (standby), <25mA (alarm) |
Operating temperature |
0 °C - 40 °C |
Operating humidity |
< 93 % |
Mounting |
Ceiling or wall |
Warranty |
3 years |
Product lifetime |
10 years |
Accessories |
Screws, dowels and battery |
5 Status of Smoke Alarm |
|
Standby Status |
Red LED flashes once every 40 seconds indicating the smoke alarm is operating properly. |
Alarm & Test Status |
For alarm detected smoke : alarm with the red LED flashing; For alarms triggered by wireless signal: alarm without red LED flashing |
Low Battery Voltage Status |
An intermittent chirp with red LED flashes once every 40 seconds. |
Fault Status |
the alarm chirps between two flashes every 40 seconds |
Silence Mode Status |
the red LED will flash once every 8 seconds after pressing the test button in alarm status |
Problems |
Solutions |
Smoke alarm does not sound when testing NOTE: Push test button for at least 5 seconds while testing. |
Remove smoke alarm from bracket and check the battery is properly connected to battery connector. Replace the battery. If there are still failures during warranty, you can return to your retailer. If the unit is out of warranty, please replace a new alarm. |
The alarm chirps with red LED flashing once every 40 seconds. |
The battery is under low battery voltage status, please replace the battery referring to Replace Battery section. |
The alarm chirps every 40 seconds. (The alarm goes into fault mode) |
Clean smoke alarm referring to the Maintenance and Cleaning section. Change a new smoke alarm if the problem still exists. |
Smoke alarm sounds unwanted alarms intermittently or when residents are cooking, taking showers, etc. |
Press test button to pause alarm. Clean smoke alarm. Please refer to the Maintenance and Cleaning section. Move smoke alarm to new location and press test button. |
The alarm sounds different from it is used to. It starts and stops. |
Clean smoke alarm. Please refer to the Maintenance and Cleaning section. If there are still failures during warranty, you can return to your retailer. If the unit is out of warranty, please replace a new alarm. |